• head
    Online Us

    24-hour service

  • icon02
    Find Us

    Zhengzhou, China

News Center
  1. Home > 
  2. Rotary Kiln > 
  3. physical procedure of is 4031 part 14 of cement
physical procedure of is 4031 part 14 of cement

physical procedure of is 4031 part 14 of cement

Sep 10, 2013· Section Name: Cement and Concrete (CED 2) Designator of Legally Binding Document: IS 4031-14 Title of Legally Binding Document:Methods of physical test for hydraulic cement, Part14:Determination of false set Number of Amendments: Equivalence: Superceding: Superceded by: LEGALLY BINDING DOCUMENT Step Out From the Old to the New--Jawaharlal Nehru

[email protected]

Relate Product

News Detail
  • IS 4031-15: Methods of physical test for hydraulic cement
    IS 4031-15: Methods of physical test for hydraulic cement

    Section Name:CementandConcrete(CED 2) Designator of Legally Binding Document: IS4031-15 Title of Legally Binding Document: Methods ofphysicaltest for hydrauliccement,Part15: Determination of fineness by wet sieving

    Get Price
  • BIS IS 4031-14 : 1989 AMD 1 2013 | METHODS OF PHYSICAL
    BIS IS 4031-14 : 1989 AMD 1 2013 | METHODS OF PHYSICAL

    buy bis is4031-14: 1989 amd 1 2013 methods ofphysicaltests for hydrauliccement-part 14: determination of false set from sai global

    Get Price
  • physical procedure of is 4031 part 14 of cement- SFINANCE
    physical procedure of is 4031 part 14 of cement- SFINANCE

    physical procedure of is 4031 part 14 of cement XS 4031 Part 14 1989 water necessary for making up the paste which will permit the Vicat plunger to penetrate to a point 28 to 36 mm from the top of the Vicat mould in 30 seconds of release of plunger is obtained 64 Determination of Final Penetration After completion of initial penetration reading

    Get Price
  • BIS IS4031-14: 1989 AMD 1 2013 | METHODS OFPHYSICAL
    BIS IS4031-14: 1989 AMD 1 2013 | METHODS OFPHYSICAL

    buy bis is4031-14: 1989 amd 1 2013 methods ofphysicaltests for hydrauliccement-part 14: determination of false set from sai global

    Get Price
  • SPECIFIC GRAVITY/DENSITY OF HYDRAULICCEMENT(IS:4031-Part
    SPECIFIC GRAVITY/DENSITY OF HYDRAULICCEMENT(IS:4031-Part

    May 04, 2013· Overview Specific gravity is defined as the ratio between the weight of a given volumeof cementand weight of an equal volume of water. Apparatus Measuring Instruments NAME CAPACITY / RANGE / SIZE ACCURACY / LEAST COUNT Lechatelier flask Balance Water bath Other Apparatus Tray Environmental Conditions Temp Relative humidity TestProcedureDry the Le-chatelier […]

    Get Price
  • IS4031-10: Methods ofphysicaltests for hydrauliccement
    IS4031-10: Methods ofphysicaltests for hydrauliccement

    Section Name:CementandConcrete(CED 2) Designator of Legally Binding Document: IS4031-10 Title of Legally Binding Document: Methods ofphysicaltests for hydrauliccement,Part10: Determination of drying shrinkage Number of Amendments: Equivalence: Superceding: Superceded by: LEGALLY BINDING DOCUMENT Step Out From the Old to the New ...

    Get Price
  • List of IS Codes forCementandConcrete
    List of IS Codes forCementandConcrete

    IS4031(Part13):1988 Methods ofphysicaltests for hydrauliccement:Part13 Measurement of water retentivity of masonrycement. IS4031(Part 14):1989 Methods ofphysicaltests for hydrauliccement:Part 14Determination of false set. IS4031(Part15):1991 Methods ofphysicaltest for hydrauliccement:Part15 Determination of fineness by wet ...

    Get Price
  • COMPRESSIVE STRENGTH OF HYDRAULICCEMENT(IS:4031-Part…
    COMPRESSIVE STRENGTH OF HYDRAULICCEMENT(IS:4031-Part…

    May 04, 2013· TestProcedure. Take 200 gof cementand 600 g of standard sand and mix them dry thoroughly. Add of water (where P is % of water required for preparing paste of standard consistency) to the dry mixof cementand sand and mix thoroughly for a minimum of 3 minutes and maximum of 4 minutes to obtain a mix of uniform colour. If even in 4 minutes uniform colour of the mix is not …

    Get Price
  • Evaluation ofphysicalstability and leachability of
    Evaluation ofphysicalstability and leachability of

    Portland PozzolonaCement(PPC) of grade 43 confirming to IS 1489 (Part1): 1991 was used as the binder system. PPC is commercially availablecementwith 10–25% fly ash interground in it. Mortar cube steel moulds of 70.6 mm × 70.6 mm × 70.6 mm were used for casting thecement–sludge mixture.

    Get Price
  • [PDF] IS :4031( ALL PARTS ) CODE Book Free Download
    [PDF] IS :4031( ALL PARTS ) CODE Book Free Download

    Download IS :4031( ALL PARTS ) IS Code Book (Indian Standards) – We have compiled a Best & Standard Reference Books on Civil Engineering (Indian Standards) IS Code Subject.These books are used by students of top universities, institutes and colleges. IS :4031…

    Get Price
  • BIS IS4031-3 : 1988(R2014) | METHODS OFPHYSICALTESTS
    BIS IS4031-3 : 1988(R2014) | METHODS OFPHYSICALTESTS

    buy bis is4031-3 : 1988(r2014) methods ofphysicaltests for hydrauliccement-part3: determination of soundness from sai global

    Get Price
  • Normal or Standard Consistencyof cement| Vicat Apparatus
    Normal or Standard Consistencyof cement| Vicat Apparatus

    Oct 01, 2017· The Consistencyof cementtest is performed to determine the amount of water content that is to be added incementto attain Standard consistency or normal consistencyof cement. (or) Amount of water added incementto penetrate the Vicat plunger up to a depth of 5-7mm from the bottom of the Vicat mould or 33-35mm from top of the Vicat Mould.

    Get Price
CONTACT CONTACT US

Are You Looking for A Consultant?

toTop
Click avatar to contact us
Hi,may I help you with products, price, etc?
Chat Online